Safety Factor: Designed to 5:1, for the load cell and the lifting eye. Average
straightening load of the hook is at least 4 times the capacity.
Proof Load: Each system proof-loaded to 200% of capacity (certified) up to a test force of 400t.
Accuracy: ± 0.1% of full range.
Durability: Robust extruded aluminum indicator housing, iridized and polyurethane coated.
Display: 5 digit, 1" (25mm) liquid crystal display and annunciator; two-level
overload state, max. value (peak hold), low battery, tare state (gross
or net), measuring units, sleep state, charge, and programming
instructions. Standard number of measurements per second: 1.
Functions: Zero. Tare. Low battery warning. Max. (peak hold). Two-level overload
visual alarms. User calibration. Sleep mode after 60 sec. in zero
value, awakes automatically when loaded. |
|
Units: available in the following measurement readings: metric tons, short
tons (2000 lbs), kgs, lbs, newtons, deca newtons, k. newtons.
Load Cell Material: Made of high-strength, aerospace quality, alloy steel, polyurethane coated.
Indicator Material: Extruded aluminum.
Power: 3 x AA (“finger”) 1.5 Volt Alkaline disposable batteries. Batteries
rated 3AH will function for at least 2000 hours (at least three months
of continuous working). Occasional use will extend the life of the
batteries, up to several years. Adding certain options will shorten the
life of the batteries. All settings retained at power off.ined at power
off.
Cable: Supplied with 16' / 5m cable.
Calibration: User calibration. Initial factory calibration, fully traceable (certified).
Temperature Range: -15°F to +175°F
(-25°C to +80°C).
Environmental: Weatherproof, NEMA 4, IP65. |
|
- 1 or 2 user-adjustable set points
- Additional 2"/50mm LCD display
with cable connection to indicator
- Additional 4"/100mm LED display
with cable connection to indicator
- Additional spare cable in 15ft/5m
increments
- Analog output: 0 to 1V/0 to 2V/0 to 3V
- Analog output: 4 to 20 mA
- Baud rate, user-selectable
- Dampened (average) display for
unstable load
- Data logger – up to 600
measurements
- Data logger – up to 3000
measurements
- Data logger – up to 6000
measurements
- Fatigue rated load cell
- IP 67 load cell with special
off-shore connectors
- Longer extension cable in
15ft/5m increments
- Number of measurements per
second: 2/3/4/5/6/7/8/20/30, factory set
- Real-time clock
- Rechargeable batteries, with an
external charger for charging the
batteries inside the system
- RS-232 - continuous or on demand
data output, user-selectable
- RS-485 - continuous or on demand
data output, user-selectable
- Totalizer
- Units, user-selectable
|